Model | Function |
Standard Expansion Module, only compatible with the main unit JH/JHM/JHC/JHCM/JH2/JH2M series. Cannot be mixed with others. Otherwise, it will be affected normal use. |
HE-2TCY | Temperature Expansion Module; 2 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 2 channels of NPN transistor output; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: 1°C PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-2TCY |
HE-2TCY2 | Temperature expansion module can work independently without matching with the main unit; 1 channel of RS485 communication interface; 2 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 2 channels NPN transistor output; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: 1°C; The module has independent PID self-tuning function The corresponding product label model is: HE-2TCY |
HE-4TCY | Temperature expansion module; 4 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 4 channels of NPN transistor output; Supports thermocouple sensors Measurement range: 0°C to 900°C Accuracy: ±1°C PID temperature control function available when used with our main PLC unit The corresponding product label model is: HE-4TCY |
HE-4TCY2 | Temperature expansion module can work independently without matching with the main unit; Equipped with 1 RS485 communication interface; 4 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 2 channels of NPN transistor outputs Supports thermocouple sensors Measurement range: 0°C to 900°C Accuracy: 1°C The module has independent PID self-tuning function The corresponding product label model is: HE-4TCY |
HE-8TC | Temperature Expansion Module; 8 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: 1°C; PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-8TC |
HE-8TC2 | Temperature expansion module can work independently without matching with the main unit; Equipped with 1 RS485 communication interface; 8 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: 1°C; PID temperature control function available when used with our main PLC unit The corresponding product label model is: HE-8TC |
HE-8TCY | Temperature Expansion Module; 8-channel temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 8-channel NPN transistor output; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: ±1°C; PID temperature control function available when used with our main PLC unit The corresponding product label model is: HE-8TC |
HE-8TCY2 | Temperature expansion module can work independently without matching with the main unit; Equipped with 1 RS485 communication interface; 8-channel temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); 8-channel NPN transistor output; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: 1°C; The module has independent PID self-tuning function. The corresponding product label model is: HE-8TC |
| HE-4PT | Temperature Expansion Module; 4 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports 3-wire PT100 or NTC sensors; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: ±1°C; PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-4PT |
| HE-4PT2 | Temperature Expansion Module; 4 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports 3-wire PT100 or NTC sensors; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: ±1°C; Equipped with 1 RS485 communication interface; PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-4PT |
| HE-8PT | Temperature Expansion Module; 8 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports 3-wire PT100 or NTC sensors; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: ±1°C; PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-8PT |
| HE-8PT2 | Temperature Expansion Module; 4 channels of temperature input (Isolation: isolated between I/O terminals and power supply; channels are also isolated from each other); Supports 3-wire PT100 or NTC sensors; Supports thermocouple sensors; Measurement range: 0°C to 900°C; Accuracy: ±1°C; Equipped with 1 RS485 communication interface; PID temperature control function available when used with our main PLC unit. The corresponding product label model is: HE-8PT |